Type of Transformer: |
- Single Phase Transformer
- Distribution Transformer (On - Load & Off - Load)
- Power Transformer
- Rectifier Transformer
- Furnace Transformer
|
 |
 |
 |
OFF-LOAD TAP CHANGING TRANSFORMER |
ON-LOAD TAP CHANGING TRANSFORMER |
POWER TRANSFORMER |
|
|
|
 |
 |
![]() |
FURNACE TRANSFORMER |
RECTIFIER TRANSFORMER |
|
|
Salient Features: |
- Higher Efficiency
- Robust Design
- More Reliable
- Easy Maintenance
|
Technical details: |
TECHNICAL & DIMENSION DATA |
|
11 KV / 433 V |
KVA |
63 |
100 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
750 |
800 |
1000 |
1250 |
1500 |
1600 |
2000 |
NO LOAD LOSS |
200 |
290 |
380 |
580 |
600 |
700 |
800 |
1100 |
1200 |
1300 |
1300 |
1500 |
1800 |
1900 |
1900 |
2200 |
LOAD LOSS |
1300 |
1860 |
2200 |
3300 |
3600 |
4200 |
5100 |
6400 |
6650 |
8500 |
8500 |
10800 |
12500 |
17500 |
19700 |
22000 |
IMPEDENCE |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.75 |
5 |
5 |
7.5 |
8 |
8 |
REGULATION AT upf. |
2.06 |
1.86 |
1.38 |
1.65 |
1.44 |
1.4 |
1.28 |
1.28 |
1.05 |
1.13 |
1.06 |
1.08 |
1 |
1.17 |
1.23 |
1.1 |
At 0.8 pf. |
4.05 |
3.95 |
3.67 |
3.83 |
3.71 |
3.69 |
3.61 |
3.61 |
3.46 |
3.51 |
3.63 |
3.8 |
3.74 |
5.38 |
5.72 |
5.63 |
NO LOAD CURRENT |
LESS THAN 3% OF FULL LOAD CURRENT |
EFFICIENCY AT upf. |
97.7 |
97.9 |
98.3 |
98.1 |
98.3 |
98.4 |
98.5 |
98.5 |
98.75 |
98.7 |
98.8 |
98.77 |
98.86 |
98.71 |
98.65 |
98.79 |
FULL LOAD At 0.8 pf. |
97.1 |
97.3 |
97.9 |
97.6 |
97.9 |
98 |
98.2 |
98.13 |
98.44 |
98.4 |
98.5 |
98.46 |
98.57 |
98.38 |
98.31 |
98.49 |
EFFICIENCY AT upf. |
98 |
98.2 |
98.6 |
98.4 |
98.6 |
98.7 |
98.8 |
98.75 |
98.96 |
98.9 |
99 |
98.99 |
98.06 |
98.96 |
98.9 |
98.02 |
75% LOAD At 0.8 pf. |
97.5 |
97.8 |
98.2 |
98 |
98.3 |
98.3 |
98.5 |
98.45 |
98.72 |
98.6 |
98.7 |
98.74 |
98.83 |
98.7 |
98.65 |
98.78 |
EFFICIENCY AT upf. |
98.4 |
98.5 |
98.8 |
98.6 |
98.8 |
98.8 |
98.9 |
98.92 |
99.09 |
99.1 |
99.1 |
99.16 |
99.21 |
99.16 |
99.91 |
99.23 |
50% LOAD At 0.8 pf. |
98 |
98.1 |
98.5 |
98.2 |
98.5 |
98.6 |
98.7 |
98.65 |
98.86 |
98.8 |
98.9 |
98.95 |
99.02 |
98.95 |
99.89 |
99.03 |
APPX. CORE & WINDING |
240 |
325 |
410 |
480 |
620 |
670 |
830 |
920 |
1160 |
1330 |
1340 |
1540 |
1920 |
2080 |
2120 |
2660 |
WEIGHT TANK & FITTING |
190 |
220 |
285 |
340 |
400 |
400 |
520 |
630 |
700 |
950 |
950 |
1290 |
1410 |
2080 |
2080 |
2300 |
IN KG. OIL |
115 |
160 |
190 |
215 |
280 |
280 |
365 |
375 |
480 |
580 |
580 |
720 |
845 |
990 |
990 |
1105 |
TOTAL |
545 |
705 |
885 |
1035 |
1300 |
1350 |
1715 |
1925 |
2340 |
2860 |
2870 |
3550 |
4175 |
5150 |
5190 |
6065 |
APPX. QTY OF OIL IN LTRS |
135 |
185 |
220 |
245 |
320 |
320 |
420 |
430 |
550 |
670 |
670 |
830 |
970 |
1140 |
1140 |
1270 |
OVER ALL LENGTH |
810 |
1170 |
1170 |
1440 |
1620 |
1620 |
1440 |
1440 |
1540 |
1890 |
1980 |
1980 |
1980 |
2340 |
2340 |
2430 |
DIMENSION BREADTH |
810 |
900 |
900 |
990 |
1170 |
1170 |
1170 |
1350 |
1440 |
1440 |
1800 |
2250 |
2250 |
2520 |
2520 |
2880 |
IN mm HEIGHT |
1260 |
1440 |
1440 |
1530 |
1620 |
1620 |
1800 |
1800 |
1890 |
2250 |
2340 |
2340 |
2340 |
2880 |
2880 |
2970 |
|
22 KV / 433 V |
22-11 KV / 433 V |
KVA |
63 |
100 |
200 |
250 |
315 |
500 |
750 |
1000 |
1250 |
200 |
250 |
315 |
500 |
750 |
1000 |
1250 |
NO LOAD LOSS |
300 |
400 |
580 |
600 |
620 |
1380 |
1400 |
1700 |
1730 |
650 |
710 |
650 |
1450 |
1400 |
1700 |
1850 |
LOAD LOSS |
1350 |
1900 |
3400 |
3700 |
4000 |
6900 |
8300 |
11000 |
12100 |
3400 |
3700 |
4000 |
7000 |
8300 |
11000 |
12900 |
IMPEDENCE |
4.85 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
5 |
5 |
6 |
4.5 |
4.5 |
4.5 |
4.5 |
5 |
5 |
6 |
REGULATION AT upf. |
2.14 |
1.9 |
1.7 |
1.48 |
1.27 |
1.38 |
1.1 |
1.1 |
0.96 |
1.7 |
1.48 |
1.27 |
1.4 |
1.1 |
1.1 |
1.03 |
At 0.8 pf. |
4.08 |
3.97 |
3.86 |
3.73 |
3.61 |
3.67 |
3.81 |
3.81 |
4.32 |
3.86 |
3.73 |
3.61 |
3.69 |
3.81 |
3.81 |
4.37 |
NO LOAD CURRENT |
LESS THAN 3% OF FULL LOAD CURRENT |
EFFICIENCY AT upf. |
97.4 |
97.7 |
98 |
98.3 |
98.5 |
98.3 |
98.7 |
98.73 |
98.89 |
98 |
98.2 |
98.52 |
98.31 |
98.71 |
98.73 |
98.82 |
FULL LOAD At 0.8 pf. |
96.7 |
97.1 |
97.5 |
97.9 |
98.2 |
97.9 |
98.4 |
98.41 |
98.62 |
97.5 |
97.8 |
98.15 |
97.89 |
98.38 |
98.41 |
98.53 |
EFFICIENCY AT upf. |
97.8 |
98 |
98.3 |
98.6 |
8.79 |
98.6 |
98.9 |
95.95 |
99.09 |
98.3 |
98.5 |
98.77 |
98.56 |
98.92 |
98.95 |
99.03 |
75% LOAD At 0.8 pf. |
97.2 |
97.6 |
97.9 |
98.2 |
98.5 |
98.3 |
98.7 |
98.69 |
98.86 |
97.9 |
98.1 |
98.47 |
98.29 |
98.65 |
98.69 |
98.79 |
EFFICIENCY AT upf. |
98 |
98.2 |
98.6 |
98.8 |
99 |
97.8 |
99.1 |
99.11 |
99.24 |
98.5 |
98.7 |
98.95 |
98.72 |
99.07 |
99.11 |
99.19 |
50% LOAD At 0.8 pf. |
97.5 |
97.8 |
98.2 |
98.5 |
98.7 |
98.5 |
98.8 |
98.89 |
99.05 |
8.13 |
98.4 |
98.69 |
98.4 |
98.84 |
98.89 |
98.98 |
APPX. CORE & WINDING |
255 |
330 |
535 |
600 |
700 |
1030 |
1330 |
1600 |
1960 |
545 |
600 |
710 |
1030 |
1340 |
1610 |
1975 |
WEIGHT TANK & FITTING |
210 |
265 |
380 |
410 |
430 |
680 |
980 |
1330 |
1425 |
380 |
420 |
445 |
690 |
1000 |
1350 |
140 |
IN KG. OIL |
1901 |
210 |
280 |
292 |
325 |
475 |
635 |
770 |
950 |
280 |
320 |
350 |
495 |
645 |
790 |
965 |
TOTAL |
655 |
805 |
1195 |
1305 |
1455 |
2185 |
2945 |
3700 |
4335 |
1205 |
1340 |
1505 |
2215 |
2985 |
3750 |
4390 |
APPX. QTY OF OIL IN LTRS |
220 |
240 |
320 |
340 |
375 |
545 |
730 |
890 |
1090 |
320 |
370 |
400 |
570 |
740 |
910 |
1110 |
OVER ALL LENGTH |
900 |
1260 |
1530 |
1620 |
1620 |
1740 |
1890 |
1980 |
2070 |
1530 |
1620 |
1620 |
1740 |
1890 |
1980 |
2070 |
DIMENSION BREADTH |
900 |
900 |
1080 |
1170 |
1170 |
1350 |
1440 |
2250 |
2340 |
1080 |
1170 |
1170 |
1350 |
1440 |
2250 |
2340 |
IN mm HEIGHT |
1440 |
1530 |
1710 |
1620 |
1710 |
1890 |
2340 |
2430 |
2520 |
1710 |
1710 |
1800 |
1980 |
2340 |
2430 |
2520 |
|
|